Eaton Tripp Lite Series PDU Switched ATS 200-240V 16/20A 8 C13 2 C19 C20 Horizontal 1URM - horizontal rackmount - power

$1,370.30
$867.82
Mfg # PDUMH20HVATNET CDW # 2113895

Quick tech specs

  • 3.2-3.8kW single-phase ATS/Switched PDU 200-240V 1U Horizontal w/ 10 outlets and 12ft cord
  • 10 outlets (8 C13/ 2 C19); 2 C20 inputs 12ft cord
  • Primary and secondary inputs connect to any two compatible power sources
  • PDU/ Power Distribution Unit/ PDU Strip/ Switched PDU/ rack pdu/ pdus/ datacenter pdu/ network pdu/ Horizontal PDU
  • Enables redundant A/B power option for single-corded network devices
  • Individually switched outlets network interface and 2 digit current meters
View All View More

Know your gear

Tripp Lite's 200-240V 16A Switched, Metered PDU system with Automatic Transfer Switching (ATS) offers 8 switched C13 outlets and 2 unswitched C19 outlets, plus a digital display to indicate total connected equipment power consumption level in amps. Switched outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup. Built-in web/network monitoring card enables remote power monitoring and programmable or real-time outlet control. Remote interface displays status of input power, load capacity and outlet power status via secure network or web browser interface. Offers individual outlet control to power on, off, or cycle AC output to regain control of locked-up servers and other network devices. Programmable load ramping and shedding enables user-configurable startup and shutdown sequences, including UPS load management to automatically increase runtime for the most critical connected items by shutting down less critical items at user-determined intervals. Supports notification and logging of input power status, event notification, output power and output loading conditions. Supports 1U rackmount installation in a 2 or 4 post racks.

Integrated ATS / Auto-Transfer Switch provides a redundant power option for networking and server applications with non-redundant internal power supplies. When both the PRIMARY and SECONDARY C20 inlets are connected to two separate building circuits, UPS systems or other power sources, the PDU automatically will provide ATS protection to connected loads. In ATS mode, the PDU will normally maintain continuous output to all outlets as derived from the primary C20 input cable. If the primary power source becomes unstable or fails altogether in relation to the secondary, the ATS will switch over to the secondary power source until the primary input is restored a

Key Features
200-240V 16A Switched, Metered PDU system with Automatic Transfer Switch (ATS) option
Two C20 inlets support connection to Primary and optional Secondary power sources
Built-in C20 inlets support a variety of user-supplied cordsets
Front panel digital ammeter displays power consumption in amps
Web/Network monitoring card enables remote power monitoring and control of power to each switchable C13 outlet
8 built-in C13 switched outlets and 2 unswitched C19 outlets
ATS function enables setup for hot-swappable UPS maintenance bypass, dual UPS protection or dual AC input redundancy for critical single-corded network hardware (ATS function requires the use of a full time sine wave online UPS on the Primary input, like Tripp Lite's SmartOnline series)
ATS functionality with 2-5 millisecond transfer time is supported by any two 200-240V AC power sources, regardless of phase angle, to offer support for a variety of unique redundant power applications
Small 1U rackmount format installs in only one rack space with a maximum installed depth of 14.8 inches
Also supports 0U vertical mounting in the cable managment area of many rack enclosures
Individually controlled outlets provide load management power control to networked equipment
Sequential outlet turn on eliminates power up in-rush of connected devices on initial start-up
Typical Applications

Ideal for configurations requiring a simple PDU that displays power consumption in amps
Optional-use ATS function makes this system ideal for adding redundancy to single corded devices
ATS function adds hot-swap and maintenance bypass function to standard UPS configurations

Package Includes

Switch, Metered PDU with ATS Support
User manual with warranty information
$1,370.30
$867.82
Advertised Price
Availability: 3-5+ Days
Add to Compare

Enhance your purchase

Better Together

Current Item
Eaton Tripp Lite Series PDU Switched ATS 200-240V 16/20A 8 C13 2 C19 C20 Horizontal 1URM - horizontal rackmount - power

This Item: Eaton Tripp Lite Series PDU Switched ATS 200-240V 16/20A 8 C13 2 C19 C20 Horizontal 1URM - horizontal rackmount - power

$867.82

Total Price: